BLDSC - MINUS 62 INSTANT CHILLER 1669-30S
- MSDS: BLDSC
- Manufacturer: TECH SPRAY
- Product Name: MINUS 62 INSTANT CHILLER 1669-30S
- National Stock Number: 6850-00N019061
Product Identification
Product ID:MINUS 62 INSTANT CHILLER 1669-30S
MSDS Date:08/06/1988
FSC:6850
NIIN:00N019061
MSDS Number: BLDSC
Responsible Party
US
Emergency Phone: 806-372-8523
Info Phone: 800-692-4677 OR 800-858-4043
Preparer: G UNRUH
Cage: DO989
Contractor
Telephone: 806-372-8523
Cage: 54700
Ingredients
DICHLORODIFLUOROMETHANE (SARA III)
CAS: 75-71-8
RTECS: PA8200000
Fraction By Weight: 100%
OSHA PEL 1000 PPM
ACGIH TLV: 1000 PPM; 9192
EPA Report Quantity: 5000 LBS
DOT Report Quantity: 5000 LBS
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INHAL: DIZZINESS. EYES: MODERATE TO
SEVERE IRRITATION. WARNING! CAN FREEZE TISSUE RESULTING IN SEVERE
FROSTBITE. SKIN: MODERATE TO SEVERE IRRITATION WITH DEFATTING.
WARNING! PROLONGED EXPOSURE CAN FRE EZE TISSUE RESULTING IN SEVERE
FROSTBITE. INGEST: RESPIRATORY DISTRESS, VOMITING, NAUSEA, POSSIBLE
UNCONSCIOUSNESS.
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:SEE HEALTH HAZARDS.CHLOROCARBON/
CHLOROFLUOROCARBON (CFC) MATERIALS HAVE PRODUCED SENSITIZATION OF
THE MYOCARDIUM TO EPINEPHRINE IN LAB ANIMALS AND COULD HAVE A
SIMILAR EFFECT IN HUMANS. ADRENOMIMETIC S (E.G.,EPINEPHRINE)MAY BE
CONTRA-INDICATED EXCEPT FOR LIFE-SUSTAINING USES IN HUMANS ACUTELY
OR (SEE SUPPL DATA)
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
First Aid
First Aid:INHAL: MOVE VICTIM TO FRESH AIR. EYE: FLUSH WITH CLEAR WATER
FOR AT LEAST 15 MIN, SEEK IMMEDIATE MEDICAL ATTENTION. SKIN: WASH
WITH EMOLLIENT SOAP AND WATER. FOR FROSTBITE SEEK IMMEDIATE MEDICAL
ATTEN TION. INGEST: INDUCE VOMITING WITH TEPID SALT WATER. KEEP
VICTIM WARM, SEEK IMMEDIATE MEDICAL ATTENTION. NEVER GIVE AN
UNCONSCIOUS PERSON ANYTHING BY MOUTH!
Fire Fighting
Flash Point Method:TCC
Flash Point:NONE
Extinguishing Media:EXTINGUISHING MEDIA SUITABLE FOR SURROUNDING FIRE .
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA AND FULL
PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:DO NOT STORE AEROSOL CANS IN DIRECT
SUNLIGHT OR ABOVE 120 F.
Accidental Release
Spill Release Procedures:VENTILATE AREA.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:DO NOT STORE AEROSOL CANS IN DIRECT
SUNLIGHT OR ABOVE 120 F.
Other Precautions:KEEP OUT OF REACH OF CHILDREN! FOR INDUSTRIAL USE
ONLY. NO SMOKING IN AREA OF USE. DO NOT USE IN THE GEN VICIN OF ARC
WELDING, OPEN FLAMES OR HOT SURFACES. HEAT AND/OR UV RADIATION MAY
CAUSE THE FORMA TION OF HCL AND/OR PHOSGENE .
Exposure Controls
Respiratory Protection:IF APPLICABLE - NIOSH/MSHA APPROVED ORGANIC
VAPOR MASK ABOVE TLV.
Ventilation:LOCAL EXHAUST: AMBIENT TYPE ROOM ATMOSPHERE. EXHAUST RATE:
50-200 CFM.
Protective Gloves:BUNA-N.
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:EYEWASH.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
NONE SPECIFIED BY MANUFACTURER. SIGNS & SYMPTOMS:CHRONICALLY EXPOSED TO
CHLOROCARBONS OR CFCS.
Chemical Properties
HCC:G3
Boiling Pt:B.P. Text:-22F,-30C
Vapor Pres:74 @ 75 F
Vapor Density:4.30
Spec Gravity:1.400
Solubility in Water:INSOLUBLE
Appearance and Odor:CLEAR WATER-WHITE MOBILE LIQUID. LOW ODOR.
Percent Volatiles by Volume:100
Stability
Stability Indicator/Materials to Avoid:YES
REACTIVE ALKALI METALS.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:FORCED COMBUSTION: CO, COCL2, HF, HCL.
Disposal
Waste Disposal Methods:FORCED INCINERATION (LIQUID ONLY!) OR
CONSIGNMENT TO RECLAIMER. DISPOSAL MUST BE IN ACCORDANCE WITH
FEDERAL, STATE AND LOCAL REGULATIONS .
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.